Acoustic Fire Rated Door
The Acoustic Fire Rated Door is a metal door system designed with both fire insulation and sound reduction performance. It uses an all-steel structure with fire-resistant and acoustic filling materials, making it suitable for building areas that require reliable fire safety and controlled interior noise.
Key Features
- Integrated fire insulation and acoustic noise reduction performance
- All-steel structure with cold-formed high-quality steel plate
- Door leaf filled with non-combustible fire-resistant and sound insulation materials
- Single or double rabbet construction options
- High-quality stainless steel hardware
- Stable performance for safety-critical interior spaces
Product Overview
Fire Protection with Acoustic Control
This door combines fire insulation and sound reduction in one metal assembly, helping buildings meet both fire compartment and acoustic comfort requirements.
Steel Structure and Insulated Core
The door leaf is formed from quality cold-rolled steel and filled according to the required fire rating with non-combustible, fire-resistant, heat-insulating and sound-insulating materials.
Reliable Hardware and Sealing
High-quality stainless steel hardware, rabbet construction and acoustic sealing details support stable daily use while improving fire, escape and sound insulation performance.
Applications
Conference rooms
Control rooms
Office buildings
Hotels
Hospitals
Building areas requiring both fire safety and acoustic control
Product Views





Our Advantages
Combines fire protection, heat insulation and acoustic noise reduction
Suitable for spaces with higher sound control requirements
All-steel structure improves durability and security
Detailed sealing design supports acoustic and airtightness performance
Multiple panel thickness and finish options for project requirements
Technical Data
| Door Leaf Panel Thickness | 0.8mm / 1.2mm / 1.5mm |
| Frame Steel Thickness | 1.2mm / 1.5mm / 2.0mm |
| Door Leaf Thickness | 60mm / 70mm |
| Surface Finish | Galvanized steel electrostatic powder coating / transfer printing |
| Internal Filling | Fire-resistant filling material / acoustic felt |
| Hardware | High-quality stainless steel |
| Anti-theft Grade | Grade 3 |
| Fire Rating | Class A, A1.5h |
| Sound Insulation | Grade 3 |
| Airtightness | Positive pressure Grade 6, negative pressure Grade 6 |
| Watertightness | Grade 3 |
| Wind Pressure Resistance | Grade 5 |
| Thermal Insulation | Grade 5 |
Packaging
Standard export packaging according to door size, acoustic seal configuration and hardware set
Have questions about this product?
Contact UsFrequently Asked Questions About Steel Fire Rated Doors
What is the fire rating of this steel fire door?
This steel fire rated door can be supplied with different fire integrity ratings depending on the project requirement and available test scope. Buyers should confirm the required fire rating, local standard, and documentation needs before ordering. To discuss your project requirement, visit the SNRIDA contact page for a project-specific response.
Can this steel fire door be used for export projects?
Yes. This steel fire door is designed for commercial, residential, and industrial building projects. For export projects, SNRIDA can provide product specifications, technical drawings, packing details, and available test documents where applicable. See the fire door manufacturer overview page for export project coordination.
What documents can be provided for this steel fire door?
Depending on the project requirement, SNRIDA can provide product specifications, technical drawings, commercial invoice, packing list, product photos, and available certificates or test reports where applicable. Buyers should confirm required documents with their contractor, consultant, or customs broker before shipment. For the broader import process, see the how to import fire doors from China guide.
Can hardware openings be prepared before shipment?
Yes. Hinge positions, lock holes, closer preparation, panic bar preparation, and other hardware openings can be prepared according to approved drawings. Buyers should confirm hardware models and opening direction before production.
What is the HS code reference for steel fire doors?
Steel fire doors are commonly reviewed under HS heading 7308.30 for iron or steel doors and frames. However, the final HS code may vary by destination country, door structure, hardware configuration, and customs broker review. Buyers should confirm the final classification with their local customs broker before shipment. See the fire door HS code import classification guide for more detail.
Related Products

Steel Fire Rated Door
Steel fire rated door with galvanized steel leaf, fire-resistant core and certified fire integrity options

Oversized Fire Rated Door
Custom oversized fire rated steel door for large openings in halls, exhibition spaces, corridors and equipment access areas

Glass Fire Rated Door
Fire rated glass door with steel or stainless steel frame for commercial, office, hospital and residential interiors
Need more details about this product?
Send us your requirement and we will reply with specifications, pricing, and delivery details.